Sign In | Join Free | My himfr.com
Home > Low Voltage Power Cable >

Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor

    Buy cheap Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor from wholesalers
     
    Buy cheap Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor from wholesalers
    • Buy cheap Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor from wholesalers

    Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor

    Ask Lasest Price
    Brand Name : SUNWIN
    Certification : ISO9001, ISO14001, OHSAS18001
    Price : Negotiable
    Delivery Time : 10 day
    Payment Terms : 30% deposit, the balance is settled on the delivery date
    Supply Ability : 100,000 m / month
    • Product Details
    • Company Profile

    Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor

    Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor


    Technical data

    Power and control cable acc. to DIN VDE 0276 part 604,

    HD 604 S1 part 1 and part 5G

    Temperature range

    during installation -5°C to +50°C fixed installation -30°C to +90°C

    Permissible operating temperature

    at conductor +90°C

    Nominal voltage U0/U 0,6/1 kV

    Test voltage 4 kV

    Minimum bending radius

    single-core 15x cable Ø multi-core 12x cable Ø

    Radiation resistance

    up to 100x106 cJ/kg (up to 100 Mrad)

    Caloric load values

    see Technical Informations


    Cable structure

    Aluminium-conductor, to DIN VDE 0295 cl.1 or cl.2, single-wire or multi-wire,

    BS 6360 cl.1 or cl.2, IEC 60228

    cl.1 or cl.2

    Core insulation of cross-linked polyethylene (XLPE)

    compound type 2XI1 to HD 604 S1

    Core identification to DIN VDE 0293-308

    Core identification for 3+½ conductor J-type: GN-YE (½), BN, BK, GY

    O-type: BU (½), BN, BK, GY

    Cores stranded in layers (for multi-core cables)

    Overall filled inner sheath

    Covered by filling compound or

    Outer sheath of thermoplastic polyolefine, ompound type HM4 to HD 604 S1

    Sheath colour black


    Properties

    Halogen-free, no separation of corrosive or toxic gases

    Limited propagation of fire

    Low smoke development

    The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers tests

    Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24,

    IEC 60332-3-24 (previously DIN VDE 0472

    part 804 test method C)

    Corrosiveness of combustion gases

    acc. to DIN VDE 0482 part 267,

    DIN EN 50267-2-2, IEC 60754-2

    (equivalent DIN VDE 0472 part 813)

    Halogen-free acc. to DIN VDE 0482

    part 267, DIN EN 50267-2-1, IEC 60754-1

    (equivalent DIN VDE 0472 part 815)

    Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2,

    IEC 61034-1+2, BS 7622 part 1+2

    (previously DIN VDE 0472 part 816)


    Note

    re = round conductor, single-wire rm = round conductor, multi-wire sm = sectional conductor, mutli-wire

    J-version = with GN-YE conductor

    O-version = without GN-YE conductor

    AWG sizes are approximate equivalent values. The actual cross-section is in mm².

    LS0H = Low Smoke Zero Halogen


    Application

    Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation

    in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor Q applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.

    applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.

    CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.


    Part no. No.cores x Outer Ø Alu Weight AWG-No.

    J type O type cross-sec. app. mm weight app. mm² kg / km kg / km

    50073501281 x 25 rm9,973,0132,04
    50074501291 x 35 rm11,0102,0166,02
    50075501301 x 50 rm12,5145,0211,01
    50076501311 x 70 rm14,1203,0283,02/0
    50077501321 x 95 rm16,1276,0376,03/0
    50078501331 x 120 rm17,5348,0456,04/0
    53562535531 x 150 rm19,6435,0560,0300 kcmil
    50079501341 x 185 rm21,8537,0697,0350 kcmil
    53561501351 x 240 rm24,0696,0878,0500 kcmil
    50080535541 x 300 rm26,7870,01073,0600 kcmil
    50081501361 x 400 rm29,71160,01347,0750 kcmil
    50082535551 x 500 rm33,11450,01705,01000
    kcmil

    Part no.

    J type

    No.cores x Outer Ø Alu Weight AWG-No.

    O type cross-sec. app. mm weight app. mm² kg / km kg / km

    50083501373 x 16 rm16,3139,0364,06
    50084501383 x 25 rm19,6218,0530,04
    50085501393 x 35 rm22,1305,0684,02
    50086501403 x 35 se19,0305,0486,02
    50087501413 x 50 sm22,4435,0655,01
    50088501423 x 50 se21,2435,0622,01
    50089501433 x 70 sm26,1609,0903,02/0
    50090501443 x 70 se25,2609,0859,02/0
    50091501453 x 95 sm29,1827,01174,03/0
    50092501463 x 95 se27,8827,01115,03/0
    50093501473 x 120 sm32,21044,01446,04/0
    50094501483 x 120 se30,81044,01379,04/0

    Quality Low Voltage 4 Core Power Cable Radiation Resistance Aluminium Conductor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Shengyu Cable Industry Co., Ltd.
    *Subject:
    *Message: