    Bare Copper Security Low Voltage Power Cable With Improved Fire Characteristics

    Ask Lasest Price
    Brand Name : SUNWIN
    Certification : ISO9001, ISO14001, OHSAS18001
    Price : Negotiable
    Delivery Time : 10 day
    Payment Terms : 30% deposit, the balance is settled on the delivery date
    Supply Ability : 100,000 m / month
    • Product Details
    • Company Profile

    Bare Copper Security Low Voltage Power Cable With Improved Fire Characteristics

    Bare Copper Security Low Voltage Power Cable With Improved Fire Characteristics


    Technical data

    • Flame retardant, halogen-free installation cable adapted to DIN VDE 0815
    • Loop resistance
    • max. 73,2 Ohm/km

    • Temperature range
    • flexing -5°C to +50°C

      fixed installation -30°C to +70°C

    • Operating peak voltage
    • 225 V (not for purposes of

      high current and power installation)

    • Test voltage
    • core/core 500 V

      core/screen 2000 V

    • Insulation resistance min. 100 MOhm x km
    • Mutual capacitance

    max. 120 nF/km at 800 Hz (this values may be extended at

    20% with a make-up up to 4 pairs)

    • Capacitance unbalance

    max. 200 pF/100 m

    (20% of the values, but one value up to 400 pF is allowed)

    • Minimum bending radius

    6x cable Ø

    • Radiation resistance up to 100x106 cJ/kg (up to 100 Mrad)
    • Caloric load values

    see Technical Informations


    Cable structure

    • Bare copper-conductor, single-wire
    • Core insulation halogen-free, cross-linked polymer, compound type HI1 flame retardant (E90 with special foil wrapping over conductor)
    • Core identification with colour rings and ring-groups to DIN VDE 0815
    • Cores twisted to pairs, 4 pairs consist to unit, several units stranded to layers
    • Units identified by numbered tape
    • Core wrapping with special polyester and glass-fibre tape
    • Screening with alu-laminated polyester tape and solid tinned copper drain wire

    0,8 mm Ø Outer sheath halogen-free, flame retardant to DIN VDE 0207 part 24 HM2

    • Sheath colour orange

    Tests

    • Flame test acc. to DIN VDE 0482-332-3, BS 4066 part 3, DIN EN 60332-3,

    IEC 60332-3 (previously DIN VDE 0472 part 804 test method C)


    Corrosiveness of combustion gases

    acc. to DIN VDE 0482 part 267,

    DIN EN 50267-2-2, IEC 60754-2

    (equivalent DIN VDE 0472 part 813)

    systems for minimum 90 minutes. Test method to DIN 4102 part 12.

    Properties

    • No fire propagation
    • Low smoke density
    • Not for purposes of high current and power installation as well as underground laying.
    • FE 180: Insulation integrity for 180 minutes. Tests acc.to DIN VDE 0472 part 814 ฬ IEC 60331.

    Insulation integrity under direct flame propagation for the test period of 180 minutes.

    • E 30: Functionality of electrical cable systems for minimum 30 minutes. Test to DIN 4102 part 12.

    The functionality for 30 minutes assures

    when persons and animals are to be saved


    from a burning building. 30 minutes secures the functional performance of the fire warning and alarm systems, safety and spare lighting, passenger lifts with evacuation circuits, except the cables which are installed within the ladder shafts and engine rooms.

    E 90: Functionality of electrical cable

    systems for minimum 90 minutes. Test method to DIN 4102 part 12.


    (equivalent DIN VDE 0472 part 813)


    Note

    • re = round conductor, single-wire rm = round conductor, multi-wire
    • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
    • LS0H = Low Smoke Zero Halogen

    Application

    Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference impulse. Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness take a special significance, e. g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.

    CE= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.