Sign In | Join Free | My himfr.com
Home > Insulated Electrical Wire >

6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch

    Buy cheap 6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch from wholesalers
     
    Buy cheap 6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch from wholesalers
    • Buy cheap 6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch from wholesalers

    6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch

    Ask Lasest Price
    Brand Name : SUNWIN
    Certification : ISO9001, ISO14001, OHSAS18001
    Price : Negotiable
    Delivery Time : 10 day
    Payment Terms : 30% deposit, the balance is settled on the delivery date
    Supply Ability : 100,000 m / month
    • Product Details
    • Company Profile

    6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch

    6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch

    APPLICATION

    Flexible single core insulated and sheathed PVC cable. Suitable for DC power supplies on Telecoms equipment and power applications where flexibility is required.

    CONSTRUCTION

    Conductor

    Class 5 flexible copper conductor to BS EN 60228 (previously BS 6360)

    Insulation

    PVC (Polyvinyl Chloride) Type TI1 according to BS 7655

    Sheath

    PVC (Polyvinyl Chloride) Type 6 according to BS 7655

    CABLE STANDARDS

    1.5mm2 to 35mm2: generally to BS 6004 50mm2 and above: BS EN/IEC 60502-1 BS EN/IEC 60332-1-2

    The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Sunwin Cables laboratory.

    Cable performance in respect of conductor resistance, construction quality (workmanship),dimensional consistency, and other parameters are verified to published standardsand approved product drawings. Conformance to RoHS (Restriction of the use ofHazardous Substances) is determined and confirmed.

    CHARACTERISTICS

    Voltage Rating (Uo/U) 1.5mm2 to 35mm2: 450/750V 50mm2 and above: 600/1000V

    Temperature Rating

    Flexed: -15°C to +70°C

    Minimum Bending Radius

    Up to 50mm²: 3 x overall diameter Above 70mm²: 4 x overall diameter

    Sheath Colour (Insulation Colour)

    Blue (Blue) Grey (Grey) Green/Yellow (Green/Yellow) Special colours to order

    DIMENSIONS

    Sunwin PART NO. NO. OF CORES

    NOMINAL CROSS SECTIONAL AREA

    mm²

    NOMINAL THICKNESS OF INSULATION

    mm

    NOMINAL THICKNESS OF SHEATH

    mm

    NOMINAL OVERALL DIAMETER

    mm

    NOMINAL WEIGHT

    kg/km

    A1FY*0015 1 1.5 0.9 0.8 4.91 38
    A1FY*0025 1 2.5 0.9 0.8 5.35 49
    A1FY*004 1 4 1 0.9 6.25 71
    A1FY*006 1 6 1.1 0.9 7.6 101
    A1FY*010 1 10 1.2 1.1 8.56 152
    A1FY*016 1 16 1.2 1.1 9.75 215
    A1FY*025 1 25 1.4 1.1 11.5 307
    A1FY*035 1 35 1.4 1.1 12.5 405
    A1FY*050 1 50 1.4 1.4 15.1 580
    A1FY*070 1 70 1.4 1.4 16.95 769
    A1FY*095 1 95 1.6 1.5 19.1 1008
    A1FY*120 1 120 1.6 1.8 21.6 1282
    A1FY*150 1 150 1.8 1.8 23.4 1571
    A1FY*185 1 185 2 1.8 25.5 1895
    A1FY*240 1 240 2.2 1.8 28.5 2435
    A1FY*300 1 300 2.4 2.0 31.2 3050
    A1FY*400 1 400 2.6 2.1 35.3 4035

    * Sunwin Part No. shown above designate the sheath colour and insulation colour (*). For each colour substitute * for a colour code as listed below.

    e.g. A1FYBL/BL0015 = 1.5mm2 Blue (Blue)

    Colour Codes

    COLOUR Blue (Blue) Grey (Grey) Green/Yellow (Green/Yellow)
    CODE BL/BL GR/GR GY/GY

    CONDUCTORS

    Class 5 Flexible Copper Conductors

    NOMINAL CROSS SECTIONAL AREA

    mm²

    MAXIMUM DIAMETER OF WIRES IN CONDUCTOR

    mm

    MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC

    Plain Wires

    ohms/km

    1.5 0.26 13.3
    2.5 0.26 7.98
    4 0.31 4.95
    6 0.31 3.3
    10 0.41 1.91
    16 0.41 1.21
    25 0.41 0.78
    35 0.41 0.554
    50 0.41 0.386
    70 0.51 0.272
    95 0.51 0.206
    120 0.51 0.161
    150 0.51 0.129

    The above table is in accordance with BS EN 60228 (previously BS 6360)

    ELECTRICAL CHARACTERISTICS

    Current Carrying Capacity

    NOMINAL CROSS REFERENCE METHOD A REFERENCE METHOD B REFERENCE METHOD C REFERENCE METHOD F

    SECTIONAL AREA

    mm²

    (ENCLOSED IN CONDUIT IN THERMALLY INSULATING WALL ETC) (ENCLOSED IN CONDUIT ON A WALL OR IN TRUNKING ETC)

    (CLIPPED DIRECT)

    Amps

    (IN FREE AIR OR ON A PERFORATED CABLE TRAY HORIZONTAL OR VERTICAL)

    Amps

    Amps Amps

    Touching

    Spaced by One Diameter

    2 Cables Single-Phase AC or DC

    or 3 Cables Three-Phase AC flat

    2 Cables 3 or 4 Cables 2 Cables 3 or 4 Cables 2 Cables 3 or 4 Cables 2 Cables 3 Cables 3 Cables
    Single-Phase Three-Phase Single-Phase Three-Phase Single-Phase Three-Phase Single-Phase Three-Phase Three-Phase
    AC or DC AC AC or DC AC AC or DC flat AC flat and AC or DC flat AC flat AC trefoil Horizontal Vertical
    or touching touching or
    trefoil
    1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
    2.5 20 18 24 21 27 25 - - - - -
    4 26 24 32 28 37 33 - - - - -
    6 34 31 41 36 47 43 - - - - -
    10 46 42 57 50 65 59 - - - - -
    16 61 56 76 68 87 79 - - - - -
    25 80 73 101 89 114 104 131 114 110 146 130
    35 99 89 125 110 141 129 162 143 137 181 162
    50 119 108 151 134 182 167 196 174 167 219 197
    70 151 136 192 171 234 214 251 225 216 281 254
    95 182 164 232 207 284 261 304 275 264 341 311
    120 210 188 269 239 330 303 352 321 308 396 362
    150 240 216 300 262 381 349 406 372 356 456 419
    185 273 245 341 296 436 400 463 427 409 521 480
    240 321 286 400 346 515 472 546 507 485 615 569
    300 367 328 458 394 594 545 629 587 561 709 659
    400 - - 546 467 694 634 754 689 656 852 795

    Ambient temperature: 30ºC

    Conductor operating temperature: 70ºC

    The above table is in accordance with Table 4D1A of the 17th Edition of IEE Wiring Regulations.

    Voltage Drop

    NOMINAL CROSS SECTIONAL AREA

    mm²

    2 CABLES DC

    mV/A/m

    2 CABLES SINGLE-PHASE AC

    mV/A/m

    3 OR 4 CABLES THREE-PHASE AC

    mV/A/m

    Reference Methods A and B

    (enclosed in conduit or trunking)

    Reference Methods C and F (clipped direct, on tray or in free air)

    Reference Methods A and B

    (enclosed in conduit

    or trunking)

    Reference Methods C and F (clipped direct, on tray or in free air)

    Cable Touching

    Cable Spaced*

    Cable Touching Trefoil Cable Touching Flat Cable Spaced* Flat
    1.5 29.0 29.0 29.0 29.0 25.0 25.0 25.0 25.0
    2.5 18.0 18.0 18.0 18.0 15.0 15.0 15.0 15.0
    4 11.0 11.0 11.0 11.0 9.5 9.5 9.5 9.5
    6 7.3 7.3 7.3 7.3 6.4 6.4 6.4 6.4
    10 4.4 4.4 4.4 4.4 3.8 3.8 3.8 3.8
    16 2.8 2.8 2.8 2.8 2.4 2.4 2.4 2.4
    r x z r x z r x z r x z r x z r x z r x z
    25 1.75 1.80 0.33 1.80 1.75 0.20 1.75 1.75 0.29 1.80 1.50 0.29 1.55 1.50 0.175 1.50 1.50 0.25 1.55 1.50 0.32 1.55
    35 1.25 1.30 0.31 1.30 1.25 0.195 1.25 1.25 0.28 1.30 1.10 0.27 1.10 1.10 0.17 1.10 1.10 0.24 1.10 1.10 0.32 1.15
    50 0.93 0.95 0.30 1.00 0.93 0.19 0.95 0.93 0.28 0.97 0.81 0.26 0.85 0.80 0.17 0.82 0.80 0.24 0.84 0.80 0.32 0.86
    70 0.63 0.65 0.29 0.72 0.63 0.185 0.66 0.63 0.27 0.69 0.56 0.25 0.61 0.55 0.165 0.57 0.55 0.24 0.60 0.55 0.31 0.63
    95 0.46 0.49 0.28 0.56 0.47 0.18 0.50 0.47 0.27 0.54 0.42 0.24 0.48 0.41 0.16 0.43 0.41 0.23 0.47 0.40 0.31 0.51
    120 0.36 0.39 0.27 0.47 0.37 0.175 0.41 0.37 0.26 0.45 0.33 0.23 0.41 0.32 0.155 0.36 0.32 0.23 0.40 0.32 0.30 0.44
    150 0.29 0.31 0.27 0.41 0.30 0.175 0.34 0.29 0.26 0.39 0.27 0.23 0.36 0.26 0.15 0.30 0.26 0.23 0.34 0.26 0.30 0.40
    185 0.23 0.25 0.27 0.37 0.24 0.17 0.29 0.24 0.26 0.35 0.22 0.23 0.32 0.21 0.145 0.26 0.21 0.22 0.31 0.21 0.30 0.36
    240 0.18 0.195 0.26 0.33 0.185 0.165 0.25 0.185 0.25 0.31 0.17 0.23 0.29 0.16 0.145 0.22 0.16 0.22 0.27 0.16 0.29 0.34
    300 0.145 0.16 0.26 0.31 0.15 0.165 0.22 0.15 0.25 0.29 0.14 0.23 0.27 0.13 0.14 0.19 0.13 0.22 0.25 0.13 0.29 0.32
    400 0.105 0.13 0.26 0.29 0.12 0.16 0.20 0.115 0.25 0.27 0.12 0.22 0.25 0.105 0.14 0.175 0.105 0.21 0.24 0.10 0.29 0.31

    Conductor operating temperature: 70ºC r = Resistive Component

    x = Reactive Component z = Impedance Value

    *Spacings larger than one cable diameter will result in a larger voltage drop.

    The above table is in accordance with Table 4D1B of the 17th Edition of IEE Wiring Regulations.

    For cables having conductors of 16mm2 or less cross-sectional area their inductances can be ignored and (mV/A/m)r values only are tabulated. For cables having conductors greater than 16mm2, cross-sectional area the impedance values are given as (mV/A/m)z, together with the resistive component (mV/A/m)r and the reactive component (mV/A/m)x.

    The above paragraph is extracted from Appendix 4 of the 17th Edition of IEE Wiring Regulations.

    The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.

    Quality 6381Y / BS 6004 PVC Copper Electrical Cable Multi Core For Apparatus Switch for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Shengyu Cable Industry Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)