Sign In | Join Free | My himfr.com
Home > Overhead Power Lines >

High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

    Buy cheap High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215 from wholesalers
     
    Buy cheap High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215 from wholesalers
    • Buy cheap High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215 from wholesalers

    High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

    Ask Lasest Price
    Brand Name : SUNWIN
    Certification : ISO9001, ISO14001, OHSAS18001
    Price : Negotiable
    Delivery Time : 10 day
    Payment Terms : 30% deposit, the balance is settled on the delivery date
    Supply Ability : 100,000 m / month
    • Product Details
    • Company Profile

    High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

    High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215


    APPLICATION

    AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.


    CONSTRUCTION

    Conductor

    Aluminium alloy conductor Type AL2 to AL7 as per EN 50183 to BS 215


    CABLE STANDARDS

    ASTM - B 399 Metric Units, ASTM - B 231, TS IEC 1089, DIN 48201, BS 215, UNE 21.018


    The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.


    DIMENSIONS

    ASTM Sizes


    CODE

    SIZE

    KCM

    STRANDING

    DIAMETER

    inches

    NOMINAL CROSS SECTIONAL AREA

    (sq ins)

    WEIGHT

    lbs/1000ft

    RATED STRENGTH

    (lbs)

    RESISTANCE

    ohms/1000ft

    CURRENT RATING

    Amps

    SIZE

    ACSR WITH EQUIV.DIAM. STRANDING

    Alt/Stl

    Individual wiresTotal

    DC

    20ºC

    AC

    75ºC

    AKRON30.5870.06610.1980.02428.711100.6590.785107661
    ALTON48.6970.08340.250.038245.717600.4140.493143461
    AMES77.4770.10520.3160.060872.728000.260.31191261
    AZUSA123.370.13270.3980.0968115.744600.1630.1952561/061
    ANAHEIM155.470.1490.4470.1221145.953900.130.1542962/061
    AMHERST195.770.16720.5020.1537183.767900.1030.12303423/061
    ALLIANCE246.970.18780.5630.1939231.885600.08160.09733954/061
    BUTTE312.8190.12830.6420.2456293.6110000.06440.0769460266.8267
    CANTON394.5190.14410.7210.3098370.3133000.05110.061532336.4267
    CAIRO465.4190.15650.7830.3655436.9156000.04330.0518590397.5267
    DARIEN559.5190.17160.8580.4394525.2188000.0360.04316634772617
    ELGIN652.4190.18530.9270.5124612.4219000.03090.0371729556.52617
    FLINT740.8370.14150.9910.5818695.5244000.02720.0327790636267
    GREELY927.2370.15831.1080.7282870.4305000.02170.0263908795267

    Resistance is calculated using ASTM standard increments of stranding, and metal conductivity of 52.5% IACS. AC resistance at 60 Hz.

    Current ratings are based on 75ºC conductor temperature, 250ºC ambient, 2 ft/s wind, 96/watts/sq.foot sun, 0.5 coefficients of emissivity and absorption.


    ASTM Sizes


    CONDUCTOR SIZE

    c mil

    AREA

    mm2

    NO. AND DIAMETER OF WIRESOVERALL DIAMETER OF CONDUCTORLINEAR WEIGHT

    RATED STRENGTH

    lb

    MAXIMUM DC RESISTANCE AT 20ºC

    ohms/km

    inchmminchmmkg/kmdaN
    6636033.627 x 0.09747 x 2.470.2917.41931068240.9942
    10560053.57 x 0.12287 x 3.120.3689.36148169738150.6256
    13310067.447 x 0.13797 x 3.50.41310.5187205246120.4959
    16780085.027 x 0.15487 x 3.930.46411.823525865810.3936
    211600107.217 x 0.17397 x 4.420.52213.26296326373320.3119
    400000202.6819 x 0.145119 x 3.680.72418.45605974134260.165
    45000022819 x 0.153919 x 3.910.76919.5563067191510.1487
    500000253.3519 x 0.162219 x 4.120.81120.67004764167740.1321
    550000278.6837 x 0.121937 x 3.10.85421.77698380188350.1202
    60000030437 x 0.127337 x 3.230.8922.68399138205350.1102
    650000329.3537 x 0.132537 x 3.360.92623.529109494213360.1016
    700000354.737 x 0.137537 x 3.490.96224.4397810220229670.0944
    75000038037 x 0.142437 x 3.610.99525.2710501094024630.088
    800000405.3637 x 0.14737 x 3.731.0226.1111811680262480.0826
    90000045637 x 0.15637 x 3.961.0927.72126013150295510.0733
    1000000506.737 x 0.164437 x 4.171.1529.2140014610328320.066

    ASTM Sizes Metric Units


    CODE

    SIZE

    KCM

    NOMINAL SIZE

    mm2

    STRANDING

    DIAMETER

    inches

    WEIGHT11

    lbs/1000ft

    RATED STRENGTH2

    kg

    RESISTANCE3

    ohms/1000ft

    CURRENT RATING4

    Amps

    SIZE

    mm2

    ACSR WITH EQUIV.DIAM. STRANDING

    alt/stl

    Individual WiresTotal

    DC

    at 20ºC

    AC

    at 75ºC

    AKRON30.5815.571.6795.0442.75032.162.5710713.36/1
    ALTON48.6924.6772.1186.36687981.361.6214321.156/1
    AMES77.4739.2572.6728.02108.212700.8531.0219133.636/1
    AZUSA123.362.4873.37110.11172.220230.5360.63925653.316/1
    ANAHEIM155.478.7473.78511.35217.124450.4250.50929667.446/1
    AMHERST195.799.1674.24712.74273.330800.3380.40334285.036/1
    ALLIANCE246.9125.174.7714.31344.938830.2680.319395107.226/1
    BUTTE312.8158.5193.25916.29436.949890.2110.252460135.1926/7
    CANTON394.5199.9193.6618.3551.160330.1680.2532170.4626/7
    CAIRO465.4235.8193.97519.8865070760.1420.17590201.4226/7
    DARIEN559.5283.5194.35921.79781.585270.1180.142663241.726/7
    ELGIN652.4330.6194.70723.53911.399340.1010.122729281.9826/7
    FLINT740.8375.4373.59425.161035110680.08920.107790322.2726/7
    GREELY927.2469.8374.02128.151295138340.07130.0863908402.8326/7

    Weights are calculated using ASTM standard increments of stranding.

    Rated strengths are calculated by ASTM methods and converted to metric units after rounding.

    Resistance is calculated using ASTM standard increments of stranding, and metal conductivity of 52.5% IACS, AC resistance at 60 Hz.

    Current ratings are based on 751ºC conductor temperature, 250ºC ambient, 0.61 m/s wind, 1033 watts/sq. meter sun, 0.5 coefficients of emissivity and absorption.

    Quality High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Shengyu Cable Industry Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)