    Low Voltage Variable Frequency Drive Cables VFD Cable AG2 Medium Severity

    Low Voltage Variable Frequency Drive Cables VFD Cable AG2 Medium Severity


    TOXFREE ZH ROZ1-K AS VFD EMC 0,6/1kV cable has been specially designed for Variable Frequency Drive Motors and installations where it is necessary to limit the effects of electromagnetic interference (EMI).

    TOXFREE ZH ROZ1-K AS VFD EMC cable performance

    Electrical performance

    LOW VOLTAGE 0.6/1 KV


    Standard

    IEC 60502-1 / IEC 60092-353


    Approval

    CE

    DNV-GL

    ABS (in progress)

    RoHS


    Construction Product Regulation

    Cca - s1a, d1, a1 / B2ca - s1a, d1, a1


    Thermal performance

    Maximum service temperature: 90ºC.

    Maximum short-circuit temperature: 250ºC (max. 5 s).

    Minimum service temperature: -40ºC (fixed and protected installations).


    Fire performance

    Flame non-propagation based on UNE-EN 60332-1 and IEC 60332-1.

    Fire non-propagation based on UNE-EN 60332-3 and IEC 60332-3.

    LSZH (Low Smoke Zero Halogen) based on UNE-EN 60754-1 and IEC 60754-1.

    Low smoke emission based on UNE-EN 61034 and IEC 61034.: Light transmittance > 60%

    Low corrosive gases emission based on UNE-EN 60754-2 and IEC 60754-2.


    Mechanical performance

    Minimum bending radius: x10 cable diameter.

    Impact resistance: AG2 Medium severity.


    Chemical performance

    Chemical & Oil resistance: Good.


    Water performance

    Water resistance: AD5 Jets.


    Other

    Meter by meter marking.

    Ripcord.

    Electric fields resistant.


    Installation conditions

    Open Air.

    Buried.

    In conduit.


    Applications

    Industrial use.

    Variable Frequency Drive (VFD)

    TOXFREE ZH ROZ1-K AS VFD EMC cable design

    Conductor

    Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.


    Grounding Conductor

    The grounding conductor is divided into three conductors; the equivalent cross section is approximately 50% of the section of the phase conductor.


    Insulation

    Cross-linked polyethylene (XLPE)

    The standard identification of insulated conductors is the following:

    4G grey + brown + black + Green/yellow (up to 4 mm2)

    3x + 3G grey + brown + black + Green/yellow (3 x) (from 6 mm2 onwards)


    Screen

    Aluminium-polyester tape screen, helically placed over the insulated conductors. Over the tape there is a tinned copper braid screen. The tape and the braid act as a double screen to cut out all of the the electromagnetic interference.

    The screen has a cover of 100% and its total section is approximately 10% of one of the conductors.


    Outer sheath

    Polyolefin LSZH outer sheath, black colour. The ripcord allows you to gently tear the outer-sheath allowing you to gently peel it away without damaging the screen.


    Technology

    1. Conductor

    Electrolytic copper, class 5 (flexible), based on EN 60228 and IEC 60228.

    2. Grounding Conductor

    The grounding conductor is divided into three conductors; the equivalent cross section is approximately 50% of the section of the phase conductor.

    3. Insulation

    Cross-linked polyethylene (XLPE)

    The standard identification of insulated conductors is the following:

    4G grey + brown + black + yellow/green (up to 4 mm2)

    3x + 3G grey + brown + black + yellow/green (3 x) (from 6 mm2 onwards)

    4. Screen

    Aluminium-polyester tape screen, helically placed over the insulated conductors. Over the tape there is a tinned copper braid screen. The tape and the braid act as a double screen to cut out all of the the electromagnetic interference.The screen has a cover of 100% and its total section is approximately 10% of one of the conductors.

    5. Outer sheath

    Polyolefin LSZH outer sheath, black colour. The ripcord allows you to gently tear the outer-sheath allowing you to gently peel it away without damaging the screen.